Digihome Pvr80 Manual

Posted on -
162051559007

Need the Digihome PVR80 manual or GUSTB250IV pdf manual please. Hi, As far as I have checked your Digihome PVR80 is the same model as the 'Goodmans PVR80'. As far as I have checked your Digihome PVR80 is the same model as the 'Goodmans PVR80'. The Goodmans manual can be downloaded from their website as given below. Hope this helps!if more help requires pls let me know. Take care and please Remember to rate/vote and give me 4 Thumbs Up for me to continue f or Helping out the Community:). However, with the DigiHome PVR80 at £100 or the larger PVR160 at £150 from Argos, there was no way on Earth I could have recommended the Toppy at £275. The DigiHome has an EPG which looks almost identical to EPGN, and can dual record. Of course no TAPs or USB, but the gap in features is not so great.

Seller assumes all responsibility for this listing.
Last updated on 16 Jul, 2019 12:58:06 BST View all revisions
DAOR REDLE 61
mahdlO
ZD3 4LO

Item specifics

Condition:
New: A brand-new, unused, unopened and undamaged item in original retail packaging (where packaging is ... Read moreabout the condition
Type: TV Remote control
Wireless Range: 5-10 m Compatible Brand: digihome
Batteries Included: No Compatible Model: 43-287FHDDLED-CNTD
Features: Infrared, Wireless, R.C Brand: Unbranded
Custom Bundle: No MPN: RC-4848
Modified Item: No Manufacturer Colour: Black
Manufacturer warranty: 1 month Battery(ies) Included: No
Country/Region of Manufacture: China EAN: 5019706902315

SPARES-DIRECT-2015

99.9%
Sign up for newsletter

Business seller information

Spares-Direct-2015-Ltd
16 ELDER ROAD
Oldham

Digihome Pvr Manual

OL4 3DZ
Pvr80
Complete information
VAT number:
After receiving the item, cancel the purchase within
30 days
Take a look at our Returning an item help page for more details. You're covered by the eBay Money Back Guarantee if you receive an item that is not as described in the listing.
The buyer is responsible for return postage costs.
Returns accepted
Most purchases from business sellers are protected by the Consumer Contract Regulations 2013 which give you the right to cancel the purchase within 14 days after the day you receive the item. Find out more about your rights as a buyer - opens in a new window or tab and exceptions - opens in a new window or tab.
If you've lost BBC1 and BBC2 after the 4th November rescan, download firmware version 5.7 for the T810 from this website and follow the update instructions below.

If you use the Winter Hill transmitter, you may need to do a manual scan of channel 62 (after the upgrade) in orderto get the BBC North West programmes instead of BBC Wales.

  • How to rescan the PVR80
  • Photos of inside the box.
  • Photos of inverting the Hard Drive and fitting a fan

Please note that the following photos and instructions are based on the invaluable information found here, and here.

None of the original discovery work belongs to me.

As time has gone by, various notes have been added here based on feedback from people who've updated their boxes. As a result, the pagehas become a bit untidy and less easy to read. I do recommend that you read through it all in case there is something specific to your box.

  • Please note that this update is done at your own risk. You could finish with an expensive brick.
  • This procedure will NOT delete any existing recordings that you have on the PVR's Hard Drive.
  • The 'Twin Record' update is no longer an option because of the way Freeview has changed with the recent retunes.
  • You can get most versions of the firmware at www.futaura.co.uk
  • The upgrade can be done with the PVR still connected to the TV or you can remove it to a location more convenient for your PC... it doesn'tneed to be connected to the TV or aerial.

Connecting the PVR80 to the Computer

You need a serial cable to connect between the RS232 socket on your PC and the RS232 socket on the back panel of the PVR80.

The serial cable is a 'straight-through' 9-pin cable (pin 2 to pin 2, pin 3 to pin 3 etc.) with a male connector on one end and a female connector on the other. The end with the pins may have fixing screws or threaded bushes which you will need to remove to prevent themcatching on the PVR80 socket.

If your PC doesn't have an RS232 serial socket, you can use a USB converter cable. (Note the system requirements - a driver may not be available for Windows 7).

NOTE: Although I get emails from people telling me they've successfully updated the box with a USB-Serial adapter cable, I probably get as many telling me of problems. I guess alladapter cables are not the same and it has to be trial and error.

Someone who successfully used a USB-Serial cable writes:

I would advise those using a USB-serial converter cable to get the latest and correct driver for their OS from the manufacturer. Check the device and vendor IDs from:

If the USB-serial converter cable is listed here, note the 4 alpha-numeric ID codes for the Vendor (VID_XXXX) and Product (PID_XXXX) under the 'PNP Device ID' heading. The hardware manufacturer information can then be obtained by entering the ID codes in the PCI Database:

There are usually direct links from here to the latest drivers from the manufacturer's website.

Digihome pvr80 manual

After installing the correct driver, the converter cable both installed correctly and updated the firmware in the DTR80.

It's also been reported that the following USB-serial converter works well:

It should be noted that most modern PCs without an external serial (COM) port may well have the hardware already installed on the motherboard andit may be possible to easily add a suitable socket 'riser' plate at the back of the computer. Alternatively, PCI RS232 cards are available to add a serial port provided you have a spare PCI socket on the motherboard. For laptops, a Serial Port CardBus PCMCIA Card mightbe more successful than a USB-Serial adapter cable - although I haven't tried this.

Download and Extract the firmware

After downloading the 5.7 firmware, extract the .bin,Digihome Pvr80 Manual file and save it on the Windows Desktop.

Note

DigiHome DTR80: There are 2 versions of the DTR80. The first is a Vestel T810, which means it's essentially a PVR80. The later versions are Vestel T816. Check which version of the machine you have - either 'T810' or 'T816' will be on the barcode label on the underside of the machine beforedownloading the appropriate firmware.

Note for Windows versions later than XP

If you're using Vista or Windows 7, you'll need HyperTerminal

Digihome Pvr80 Manual

The Procedure

Digihome Pvr80 Instruction Manual

Disconnect the PVR80 from the mains.

Connect the serial cable between the PC and the PVR80. Leave the PVR80 disconnected from the mains.

Open Hyperterminal in Windows XP:

Start -> All Programs -> Accessories -> Communications -> Hyperterminal

Photo shows Opening Dialog of HyperTerminal.

Type a name and choose any Icon. Click 'OK'

Select 'COM1' if it isn't already selected. Type your area code if requested. Click 'OK'

If you're using a USB-serial converter cable, you may need to select a different COM number. See the instructions accompanying thecable.

Select Bits per second: 115200 and Flow control: None. Click 'Apply'. Click 'OK'
Connect the PVR80 to the mains and HyperTerminal should respond. The actual text may be different.
Select 'Transfer' -> 'Send File..' from the HyperTerminal menu.
Use the 'Browse' button to navigate to the .bin file which you extracted onto your desktop previously.
Select '1K xmodem' as the protocol type and click 'Send'.
A grey box will appear but there will be no activity. Unplug the PVR80 from the mains, wait 5 seconds and plug it back into the mains....
... The grey box should then show activity. Packets transferred and a progress bar
When the grey box disappears, wait for the main HyperTerminal screen to display the prompt again. (About 30 seconds).

Ensure there is no Hard Disc activity. Unplug the PVR80 from the mains and then unplug the RS232 cable. Relocate the box to it's normalposition (if you moved it to be closer to the PC), reconnect and power ON.